Installation Instructions - AIR-CELL® Joining Methods


PRODUCT

Application

Wire Safety Mesh Specified

Lap / Butt Join

Tape

Remarks
Glareshield®
Retroshield ®
Insulbreak ®
Permishield ®
Commercial - Flat Roof No Lapped 50mm Min. 72mm wide foil tape on top Preferred Method
Yes Lapped 50mm No Tape Required
Commercial - Pitched Roof No Lapped 50mm No Tape Required Provided no gaps or opening in join - use 72mm tape if required.
Residential - Pitched Roof No Lapped 150mm No Tape Required Provided no gaps or opening in join - use 48mm tape if required
Sheds No Butt Joined Min. 72mm wide foil tape
Framed Walls N/A Butt Joined 48mm foil tape
Cavity Walls N/A Lapped 150mm 48mm tape
Timber Floors No Lapped 150mm No tape AIR-CELL® under joist-Enclosed sub-floor
No Lapped 50mm 48mm tape AIR-CELL® under joist-Preferred Method
No Butt Joined 48mm tape AIR-CELL® over joist
Insulaire® Commercial - Flat Roof No Butt Joined Min. 72mm wide foil tape on top Preferred Method
No Min. 72mm wide foil tape on bottom
No Lapped 50mm Min. 72 wide foil tape on top
Yes Lapped 150mm No tape required
Warehouse Wall N/A Lapped 50mm Min. 72mm wide white tap on face
N/A Lapped 50mm Min. 72mm wide white tap on face

When taping AIR-CELL®, a plastic squeegee or blade must be used to apply appropriate pressure to the tape. Apply pressure as the tape is being rolled out, rahter than after application, to achieve maximum adhesion. Surfaces must be free from dust, oil or grease prior to taping.